Deep Filter Blocking: A Flat Trace May Be the Measurement Floor
TECHNICAL ANALYSIS
A filter spectrum that reaches the measurement floor does not reveal how far below that floor the true transmission lies. Accept deep blocking against a demonstrated measurement capability, not the apparent depth of a plotted line.

Optical density is a logarithmic transmission result
Semrock’s technical FAQ, published by IDEX Health & Science, explains optical density and identifies wavelength-dependent noise floors in its own measurement data. It also notes that some displayed data have a different blocking measurement limit. The undated FAQ is technical guidance, not a new filter announcement or a universal specification for spectrometers.
Write the spectral interval before comparing plots
For procurement, an OD 4 requirement corresponds to transmission no greater than 0.01% over the agreed blocking interval. The wavelength range is part of the requirement. A trace that demonstrates this at a single wavelength cannot establish rejection everywhere else that a detector can see. Keep the passband transmission requirement separate: deep rejection outside the passband does not establish useful signal throughput inside it.
TUOLAN’s proposed review asks the measurement provider to identify the supported transmission floor across that interval, together with the relevant instrument settings and background treatment. If stray light or detector noise limits the result, extending the graph axis does not extend the measurement. A displayed zero should not be converted into an infinite optical density. Ask how the reported limit was established and how uncertain points are represented.

A lower bound is useful evidence when labelled correctly
When transmission is below a validated limit, report the supported bound rather than an invented exact value. Whether that bound is sufficient depends on the agreed rejection requirement. A higher-capability measurement is needed if the existing bound cannot distinguish a passing filter from a failing one. Preserve the original spectral data and its limit statement so a later supplier comparison does not mistake plotting conventions for a coating improvement.
Related specifications
optical coating requirements · optical window substrate options
For a coated-filter enquiry, provide the blocking interval and the rejection evidence your acceptance method can resolve. Contact TUOLAN: sales@tuolango.com.