Insights
MWIR Cold Stop Matching: Carry the Detector Interface into the Drawing
TECHNICAL ANALYSIS
For a cooled MWIR camera, include the cold-stop interface in the lens review. Matching detector format and focal length alone does not establish compatibility with the detector package.

A data sheet can state more than a back focal length
Ophir’s 680473 data sheet, edition 01-2026, separately lists cold-stop geometry, cold-stop-to-detector distance and a back focal length with an assumed window arrangement. It is a historical reference, not a new announcement or a drawing for a TUOLAN configuration.
Use a common mechanical datum for both assemblies
TUOLAN recommends obtaining the detector package interface and the lens supplier’s corresponding assumptions. Mark the active plane, relevant pupil location and mounting datum in a common section view. Check whether distances are physical dimensions or optical equivalents before combining values from different documents.
List the windows between lens and detector, including their material and thickness, as part of the approved interface. A quoted distance that assumes a particular optical stack cannot simply be reused after that stack changes. Ask the optical designer to assess the revised path rather than resolving the discrepancy with a mechanical spacer alone.

Approve the actual detector and lens combination
Keep the approved interface revision with the acceptance record. Check the intended image field and pupil relationship in the assembled camera as agreed with the designer. When the detector package or window changes, reopen that interface review; retaining the same lens focal length is not evidence that the earlier approval still applies.
Related specifications
cooled MWIR lens references · optical window material options
For a cooled-camera enquiry, send the detector interface drawing and the complete intervening window stack. Contact TUOLAN: sales@tuolango.com.
Sources and editorial note
Reviewed 2026-10-29. Technical conclusions and proposed acceptance steps are TUOLAN editorial analysis. No manufacturer affiliation is implied.