Skip to content
Factory visits & supplier audits welcome by appointmentsales@tuolango.com
TUOLAN TRADE TUOLAN TRADEGLOBAL SOURCING · RELIABLE SUPPLY Contact Us

Optical Components / Infrared Lenses / 50 mm F/1 Athermalized LWIR Lens (KI805011)

LWIR 8–12 μm · Athermalized fixed-focus reference

50 mm F/1 Athermalized LWIR Lens (KI805011)

KI805011 is a 50 mm F/1 athermalized, fixed-focus LWIR reference for 8–12 μm imaging. Its published detector reference is 1280 × 1024 with 12 μm pixels, giving a 17.5° × 14° field of view. Use the detector reference together with the focal length when comparing this lens with another 50 mm configuration.

Focal length50 mm
F/#1
Working wavelength8–12 μm
Detector reference1280 × 1024 / 12 μm
50 mm F/1 Athermalized LWIR Lens (KI805011)
50 mm F/1 Athermalized LWIR Lens (KI805011) – reference image. Final coating, mount and marking are confirmed on the approved drawing.

Full parameter record

50 mm F/1 Athermalized LWIR Lens (KI805011) – published specifications

Every value below is the reference record for this configuration. Values marked as a reference, a target or a minimum are confirmed against the detector datasheet and the approved drawing before a quotation is issued.

Parameter Published value
Focal length 50 mm
F/# 1
Working wavelength 8–12 μm
Detector reference 1280 × 1024 / 12 μm
Field of view 17.5° × 14°
Average transmission ≥90% HD reference
Distortion 3%
Front coating HD
Focus Fixed (athermalized)
Depth of field 40 m–∞
Dimensions Φ60 mm × 47.46 mm
Operating / storage −40 to +60 °C / −50 to +70 °C
Sealing reference Front element IP67
Reference policy: the signed quotation, approved drawing, sample and inspection plan define the delivered performance, coating, sealing, MOQ and lead time. Values published here are engineering references for screening, not a guaranteed specification.

How to evaluate KI805011 for your system

Two lenses with the same focal length are not automatically interchangeable: detector format, pixel pitch, required image circle and mechanical interface also matter. The published envelope for KI805011 is Φ60 mm × 47.46 mm. Weight is absent from the source record and must be confirmed against the supplier drawing. The 40 m–∞ depth-of-field reference does not establish a thermal detection distance.

Configuration reference

Spectral reference 8–12 μm
Focal length / F/# 50 mm / F/1
Detector reference 1280 × 1024 / 12 μm
Reference FOV 17.5° × 14°
Published envelope Φ60 mm × 47.46 mm
Depth-of-field reference 40 m–∞
Weight reference Confirm against the supplier drawing

Athermalized is the source configuration designation. Ask for the available optical and thermal test evidence for the selected detector and temperature range. The approved drawing, quotation and acceptance plan define the supplied configuration.

Compare the published options

Published configurations: compare the detector references before selection
Model Focal length / F/# Detector reference Reference FOV Envelope
KI610011 100 mm / F/1 640 × 512 / 17 μm 6.2° × 5° Φ113.5 mm × 149.5 mm
KI805011 50 mm / F/1 1280 × 1024 / 12 μm 17.5° × 14° Φ60 mm × 47.46 mm
KIA001901 19 mm / F/0.9 640 × 512 / 17 μm 31° × 25.4° Φ30 mm × 26 mm

These field-of-view references use different detector formats. They are not a comparison on one common detector and do not guarantee interchangeability.

Can KI805011 be substituted for a 50 mm lens specified for 640 × 512?

Not on focal length alone. KI805011 is published against a 1280 × 1024 / 12 μm reference. Share the actual detector datasheet, required field of view and mechanical interface so that the configuration can be reviewed.

What to send in your RFQ

  • Detector model, resolution, pixel pitch and the detector datasheet.
  • Required horizontal and vertical field of view and working distance.
  • Mount, flange-distance requirement and the available installation envelope.
  • Operating temperature range and the optical acceptance criteria you need verified.
  • Sample and production quantities, required documents and delivery schedule.

Request configuration review for KI805011

For wider selection, browse MWIR and LWIR infrared lenses or read the MWIR vs LWIR RFQ guide.

Before this configuration is released

What to confirm with us

Send these five inputs and the quotation can be prepared against your system rather than against a catalogue headline.

01Detector type, resolution and pixel pitch of the microbolometer or cooled array
02Required horizontal field of view, or the focal length and whether focus is fixed, manual or motorized
03Athermalization target across the full operating temperature range
04Mount, flange distance, mass and the available envelope on the host system
05Sealing target, purge or desiccant handling, and the acceptance test documents required

Send the detector data and we will confirm the fit.

Share the detector type, resolution, pixel pitch, required field of view and the mechanical envelope. We will return the configuration route, the documents we can issue and the next sourcing step.

Send an RFQ

WhatsApp